Penetrant applied to a cleaned surface is drawn into surface-breaking discontinuities by capillary action. After the excess is removed, a developer draws the penetrant back out of the flaw, leaving a clear indication.
Typical applications
- Stainless steel and aluminium welds
- Crack detection on non-magnetic materials
- Intermediate checks after root pass and grinding